X'inhu l-analizzatur tal-ilma?

Analizzatur tal-ilma jista 'jiskopri kull tip ta' solidi organiċi u inorganiċi, likwidi, gassijiet, u kampjuni oħra fil-kontenut tal-ilma tal-istrument huwa ddisinjat bl-użu tal-prinċipju tal-piż tal-piroliżi, u huwa tip ġdid ta 'tagħmir tal-laboratorju ta' skoperta ta 'umdità rapida.
Applikazzjoni ta 'analizzatur ta' l-ilma
Analizzatur tal-ilma jista 'jintuża b'mod wiesa' fl-industriji kollha li jeħtieġu d-determinazzjoni rapida ta 'umdità, bħal mediċina, ikel, għalf, żrieragħ, żerriegħa tal-kolza, ħxejjex deidratati, tabakk, kimika, tè, ikel, laħam u tessuti, agrikoltura u forestrija, karta, gomma, plastik , tessuti, u industriji oħra fil-laboratorju u l-proċess ta 'produzzjoni ta' rekwiżiti ta 'determinazzjoni ta' umdità; flimkien mas-sodisfazzjon tad-determinazzjoni tal-kontenut ta 'ilma solidu, granulari, trab, kollojdali u likwidu.
L-analizzatur tal-ilma huwa wkoll użat ħafna f'diversi laboratorji, adattati għal varjetà ta 'użi, inklużi inċinerazzjoni, degassing, tnixxif, sterilizzazzjoni u sterilizzazzjoni. Stabbilizzazzjoni. Kampjun ta 'rmied u ttestjar.
Universities and research institute’s customary laboratories:
Użat biex twettaq edukazzjoni konswetudinarja u riċerka sperimentali fuq diversi laboratorji tal-fiżika, kimika, materjali, bijoloġija, elettronika, u dixxiplini oħra
Ipproċessar termali, siment, industrija tal-materjali tal-bini:
Għall-ipproċessar termali ta 'biċċiet tax-xogħol żgħar ipproċessar ħajjin, bħal tisħin ċeramika fina żgħira, żvilupp ta' materjal ġdid, eċċ.
Industrija farmaċewtika:
Għall-ittestjar tad-droga, trattament minn qabel tal-kampjun mediku, eċċ.
Industrija tal-kimika analitika:
Analiżi tal-kwalità tal-ilma bilqiegħda, analiżi ambjentali, u oqsma oħra tal-ipproċessar tal-kampjun, jistgħu jintużaw ukoll għaż-żejt u l-analiżi tiegħu.
Tipi ta' analizzatur tal-ilma
1. Miter tal-umdità Karl Fischer

Miter tal-umdità Karl Fischer ġie rikonoxxut bħala l-aktar metodu preċiż minn ħafna standards internazzjonali, bħal ISO, ASTM, DIN, BS, u JIS.
It-tester tal-umdità Karl Fischer huwa adattat għad-determinazzjoni tal-kontenut ta 'umdità ta' diversi sustanzi. Huwa l-aktar strument affidabbli għall-analiżi u l-kejl tal-umdità fil-preżent. Firxa wiesgħa ta 'applikazzjonijiet għal kampjuni solidi, likwidi u gassużi. Jekk kampjun tat-tip solidu ma jistax jitkejjel direttament, apparat ta 'vaporizzazzjoni tal-umdità jista' jiġi konness għall-kejl. Meta jintuża flimkien ma 'vaporizzatur tal-umdità, il-kundizzjonijiet tal-kejl bħall-moviment awtomatiku tal-pjanċa tal-kampjun, l-issettjar tat-temperatura tal-vaporizzazzjoni, u l-issettjar tal-ħin tal-arjazzjoni tal-gass trasportatur jistgħu jiġu kkontrollati u mkejla awtomatikament mill-unità prinċipali. Riproduċibbiltà tajba, preċiżjoni għolja, iffrankar ta 'ħin u konvenjenza.
2. Miter tal-umdità koulometriku

Tester tal-umdità koulometriku jista 'jiddetermina l-umdità fil-kampjun, jegħlbu n-nuqqasijiet tal-metodu ta' titrazzjoni Karl-Fischer bħal preċiżjoni baxxa, ammont kbir ta 'elettroliti u tħaddim tedious, bl-użu ta' ċirkwit ta 'kontroll awtomatiku avvanzat u teknoloġija ta' kontroll awtomatiku tal-kurrent elettrolitiku kbir u kurrenti, ir-riżultati tal-kejl huma direttament murija b'mod diġitali, il-forma u l-istruttura hija ġdida u ħafifa, l-istrument huwa aktar affidabbli u konvenjenti biex jintuża, u l-elettrolit jista 'jintuża ripetutament għal żmien twil. Huwa użat ħafna fil-pitrolju, kimika, enerġija elettrika, ferroviji, pestiċidi, mediċina, protezzjoni ambjentali, eċċ Għandu l-karatteristiċi ta 'analiżi veloċi, tħaddim sempliċi, preċiżjoni għolja u awtomatika.
3. Miter tal-umdità infrared

il miter tal-umdità infra-aħmar, also known as an in-line moisture meter, consists of an infrared radiation heater and an electronic balance. Its moisture determination is based on the “dry reduction method”, which is a recognized standard measurement method.
Mekkaniżmu ta 'tisħin infra-aħmar: Meta r-radjazzjoni infra-aħmar bogħod tiġi applikata għal oġġett, jistgħu jseħħu assorbiment, riflessjoni u trasmissjoni. Madankollu, mhux il-molekuli kollha jistgħu jassorbu raġġi infra-aħmar imbiegħda, iżda dawk il-molekuli polari biss li juru l-elettriku jistgħu jaħdmu. L-ilma, is-sustanzi organiċi u s-sustanzi polimeriċi għandhom proprjetajiet qawwija li jassorbu r-radjazzjoni tal-infra-aħmar bogħod. Meta dawn is-sustanzi jassorbu l-enerġija tar-radjazzjoni tal-infra-aħmar imbiegħed u jagħmlu l-molekuli u l-atomi tagħhom jivvibraw u jduru bl-istess frekwenza bħall-frekwenza tar-radjazzjoni tal-infra-aħmar bogħod, ir-reżonanza jew ir-rotazzjoni tal-molekuli u l-atomi jistgħu faċilment iseħħu, li jwasslu għal żieda kbira fil-moviment , u l-enerġija tas-sħana kkonvertita f'enerġija tas-sħana tgħolli t-temperatura interna, u b'hekk is-sustanza malajr irattab jew nixxef.
4. Miter tal-umdità tal-microwave

Miter tal-umdità microwave huwa l-użu tal-metodu ta 'penetrazzjoni tal-microwave biex jinkiseb monitoraġġ tal-umdità. Meta l-microwave permezz tal-materjali li fihom l-ilma u materjali niexfa, il-veloċità tal-propagazzjoni tal-microwave u l-intensità fid-direzzjoni tal-propagazzjoni se jkunu bidliet differenti, materjali li fihom l-ilma se jagħmlu l-veloċità tal-propagazzjoni tal-microwave intensità aktar bil-mod u dgħajfa. Il-prinċipju tal-kejl tal-miter tal-umdità tal-microwave huwa permezz tal-kxif ta 'dawn iż-żewġ proprjetajiet fiżiċi tal-bidliet tal-microwave fil-materjal permezz tal-materjal biex jiġi kkalkulat il-kontenut tal-umdità tal-materjal. Is-sinjal tal-microwave jiġi trażmess mill-antenna taħt il-conveyor belt, jaqsam il-materjal, u jiġi riċevut mill-antenna korrispondenti fuq il-qafas C. Billi tanalizza b'mod preċiż is-sinjal tal-microwave wara li taqsam il-materjal, il-frazzjoni tal-massa tal-ilma fil-materjal tiġi dedotta u r-riżultati jinħarġu f'ħin reali u jintwerew fuq l-interface tal-iskrin LCD.
5. Miter tal-umdità tal-aloġenu

Miter tal-umdità tal-aloġenu juża speċjali aloġenu sors tad-dawl li jsaħħan, li jista 'jinxef il-kampjun malajr u b'mod uniformi, u l-ebda propagazzjoni tal-midja, u m'għandu l-ebda effett fuq id-dehra tal-kampjun, proprjetajiet fiżiċi u mekkaniċi, fastness, kulur, eċċ.
Prinċipju tax-xogħol tal-analizzatur tal-ilma

In the water tester, moisture analysis methods – generally can be divided into two categories, namely, physical analysis and chemical analysis. Now there are several kinds of moisture meters, but different moisture meters have different working principles, the following is the introduction of the working principles of different moisture meters respectively.
Miter tal-umdità Karl Fischer
Karl Fischer’s method, referred to as Fischer’s method, is a volumetric splitting method for the determination of water proposed by Karl Fischer (Karl Fischer) in 1935. Fischer’s method is the most specific and accurate method for water among all kinds of chemical methods for determining the moisture of substances. Although it is a classical method, it has been improved in recent years to improve the accuracy and expand the measurement range, and has been listed as a standard method for determining moisture in many substances.
Fisher method is an iodine method, the basic principle is the use of iodine oxidation of sulfur dioxide, the need for – a quantitative amount of water to participate in the reaction.
Ir-reazzjoni ta' hawn fuq hija riversibbli. Sabiex ir-reazzjoni timxi fid-direzzjoni pożittiva u tipproċedi kwantitattivament, għandha tiżdied sustanza bażika. Sperimentalment, il-piridina hija l-aktar reaġent adattat, u l-piridina għandha wkoll l-effett li tgħaqqad ma 'jodju u dijossidu tal-kubrit biex tnaqqas il-pressjoni tal-fwar tat-tnejn. Għalhekk, ir-reaġent għandu jiġi miżjud mal-metanol jew solvent ieħor li jkun fih grupp OH reattiv biex jikkonverti s-sulfat tal-piridina fil-methosulfate tal-idroġenu tal-piridina stabbli.
Miter tal-umdità infrared
Miter tal-umdità infrared prinċipalment minn heater ta 'radjazzjoni infra-aħmar u bilanċ elettroniku biex jiddetermina l-eżattezza u l-istabbiltà tiegħu. Ħiter ta 'radjazzjoni infra-aħmar: tubu tal-vakwu tat-tungstenu jista' jirradja qrib l-infra-aħmar, karbur tas-silikon huwa heater ta 'radjazzjoni infra-aħmar ta' wavelength twil, ħġieġ tal-kwarz, u heater infra-aħmar taċ-ċeramika jista 'jirradja infra-aħmar medju.
Infrared moisture meter moisture measurement benchmark of the recognized standard measurement method of “dry reduction method” is very similar to the heating and drying, quality measurement of the infrared moisture meter. It is also called the “drying reduction method” of the accepted standard measurement method (105°C, 5 hours method), (135°C, 3 hours method), etc. By heating and drying the sample in the dryer for a long time, the change in mass before and after drying is accurately measured, and the amount of moisture is calculated.
Miter tal-umdità microwave
Miter tal-umdità microwave juża qasam microwave biex jinxef il-kampjun, li jaċċellera l-proċess tat-tnixxif. Għandu l-karatteristiċi ta 'ħin qasir ta' kejl, tħaddim faċli, preċiżjoni għolja u applikazzjoni wiesgħa, u huwa adattat għad-determinazzjoni ta 'umdità f'kampjuni solidi granulari, trab u viskuż ta' qamħ, karta, injam, tessuti, prodotti kimiċi, eċċ. jiġi applikat ukoll għad-determinazzjoni tal-umdità fil-pitrolju, pitrolju, u kampjuni likwidi oħra.
Miter tal-umdità koulometriku
Miters tal-umdità koulometriċi huma komunement użati biex jiddeterminaw l-umdità li tinsab fil-gassijiet. Dan l-approċċ huwa sempliċi biex jitwettaq u għandu reazzjoni mgħaġġla, u huwa partikolarment adattat għad-determinazzjoni ta 'ammonti żgħar ta' umdità fil-gassijiet. Jekk huwa determinat mill-metodu kimiku ġenerali, huwa ħafna minħabba l-materja diffiċli. Madankollu, il-metodu elettrolitiku mhuwiex adattat għad-determinazzjoni ta 'sustanzi alkalini jew diolefini konjugati.
Speċifikazzjonijiet u karatteristiċi tal-analizzatur tal-ilma
Analizzatur awtomatiku tal-ilma

| Valur tal-użin | |
| Eżattezza | 1mg |
| Piż tal-kalibrazzjoni | 100g |
| Firxa ta 'umdità | 0.00 ~ 100% |
| Preċiżjoni tal-iskala tal-umdità | 0.01% |
| Sors tat-tisħin | Lampa aloġena |
| daqs | 37 * 33 * 21.5cm |
Tip: Miter tal-umdità tal-aloġenu
karatteristiċi:
1. Analizzatur awtomatiku tal-ilma jadotta fanal aloġenu tat-tisħin ta 'effiċjenza għolja, jista' malajr u b'mod uniformi nixxef il-kampjun, id-data hija aktar preċiża.
2. Jintuża trej tal-kampjuni ta 'l-istainless steel, li huwa reżistenti għall-korrużjoni, u l-istrument huwa mgħammar b'bużżieqa orizzontali, li tista' żżomm il-bużżieqa orizzontali fiċ-ċentru u tagħmel ir-riżultati tal-kejl aktar preċiżi.
Analizzatur tal-ilma fuq il-bank

| Prinċipju ta 'kejl | Metodu Karl Fischer Coulomb |
| Veloċità tal-kejl | 33.3 μ g H2O/s |
| Firxa ta 'kejl | 2 μg H2O sa 120 mg H2O |
| Riżoluzzjoni tal-kejl | 0.1 μg H2O |
| Kurrent tal-elettroliżi | 0-400mA |
Tip: Miter tal-umdità Karl Fischer
karatteristiċi:
1. Disinn tal-kanal tal-provvista ta 'enerġija doppja, irażżan l-interferenza tal-kurrent
2. Aġġustament tal-pum fiżiku tal-veloċità li tħawwad, sistema ta 'aġġustament tal-veloċità indipendenti, mhux affettwata mill-interface u l-istatus tal-programm.
Prekawzjonijiet għall-użu tal-analizzatur tal-ilma

1. Fil-proċess tal-kejl tal-umdità, huwa meħtieġ li tiġi evitata l-vibrazzjoni, u l-talja fit-tarf t'isfel taċ-ċilindru tat-tisħin m'għandhiex titqiegħed kontra r-riħ.
2. Il-kampjun tal-kejl għandu jinġabar fuq il-pjanċa tal-użin, iż-żona mgħollija għandha tkopri l-wiċċ tal-qiegħ tal-pjanċa tal-użin kemm jista 'jkun, u l-ħxuna mgħollija għandha tkun irqiq kemm jista' jkun biex tiffaċilita l-evaporazzjoni sħiħa tal-ilma.
3. Fil-proċess tal-kejl tal-umdità, ma tistax tmiss iċ-ċilindru tat-tisħin b'idejk, u huwa strettament ipprojbit li tħabbat jew tivvibra direttament il-mejda tax-xogħol.
4. Minħabba li s-sistema ta 'użin ta' dan l-istrument hija tagħmir ta 'preċiżjoni, speċjalment il-parti li tittrasferixxi l-forza hija speċjalment tibża' minn pressjoni qawwija u impatt, għalhekk ipprova uża l-parentesi meta tieħu u tpoġġi l-pjanċa tal-użin kull darba, jekk tieħu u tpoġġi l-użin pjanċa bl-idejn, għandek tieħu u poġġiha ħafif.
5. Wara li jitlesta l-kejl, immedjatament neħħi l-pjanċa tal-użin trid tuża l-parentesi, sabiex ma tinħaraqx idejk. Il-parentesi m'għandhiex tmiss il-parentesi tal-użin u l-pjanċa tal-użin meta titpoġġa fl-istrument.
6. Wara l-kejl, il-pjanċa tal-użin għandha titkessaħ kompletament qabel ma titqiegħed fil-kampjun li jmiss.
Kif tixtri analizzatur tal-ilma?
Jekk inti interessat tagħna Analizzatur tal-Ilma jew għandek xi mistoqsijiet, jekk jogħġbok ikteb e-mail lil info@antiteck.com, aħna nwieġbuk kemm jista 'jkun malajr.