ANTITECK - Medical Device Assembly Automation Solution & Lab Equipment
hot-bead-steriliser

Glass Bead Sterilizer

Glass bead is scientific equipment that is used in dentistry and lab sterilization

Content
1. What is glass bead sterilizer?
    1.1. Glass bead sterilizer definition
    1.2. Application of glass bead sterilizer
2. Glass bead sterilizer temperature
3. The effect of glass bead sterilizer
4. Glass bead sterilizer specifications and features
    4.1. Small glass bead sterilizer
    4.2. High-temperature sterilization glass bead sterilizer
    4.3. Ceramic glass bead sterilizer
    4.4. Rapid glass bead sterilizer
    4.5. Mini glass bead sterilizer
5. Glass bead sterilizer most crucial part - Glass bead
6. How to use glass bead sterilizer?
7. Precautions for using glass bead sterilizer
8. How to order glass bead sterilizer?

What is glass bead sterilizer

Glass bead sterilizer definition

glass-bead-sterilizer
Glass bead sterilizer, is also known as hot bead sterilizer, that is a dry heat sterilizer that provides a safe and fast sterilization method. Its principle is to use high temperature glass beads (the principle of fast heat absorption and slow heat dissipation, to sterilize small experimental or medical equipment quickly. The purpose of the glass bead sterilizer is to maintain a stable high temperature for a long time in the instrument heating tank to achieve dry heat sterilization. The glass bead sterilizer is a compact device that can be placed in the ultra-clean bench. It can effectively sterilize small solid metal and glass instruments within ten seconds, and the glass beads can be heated to about 250°C. It is commonly used in research laboratories and is now widely used in medical, dental, biological laboratories and other scientific fields.

Application of glass bead sterilizer

bead-sterilizer
Glass bead sterilizer as a rapid disinfection instrument, in addition to being widely used for the disinfection of small mechanical instruments in laboratories, is more common in the medical field, especially in the field of dentistry and oral surgery. The glass bead sterilizer is mainly used to sterilize small handheld instruments, but also for micropropagation in dentistry because it can kill most fungi, bacteria, and viruses. In addition, glass bead sterilizers can also be used in oral surgery for root canal treatment, which is based on the fact that glass bead sterilizers can achieve rapid sterilization in a matter of seconds.rapid sterilization in a matter of seconds.

Glass bead sterilizer temperature

hot-bead-sterilizer
The glass bead sterilizer can be heated up to 240 to 250 degrees Celsius in ten to fifteen minutes and can sterilize small metal labs and medical devices within 10 seconds after the temperature rise is over.

The effect of glass bead sterilizer

Numerous studies have shown that the use of glass bead sterilizers is as effective as standard autoclaves. Glass bead sterilizers are effective in sterilizing small solid metal instruments inoculated with Staphylococcus epidermidis, Staphylococcus aureus, and Staphylococcus pneumonia, with fast and efficient sterilization.

Glass bead sterilizer specifications and features

Small glass bead sterilizer

glass-sterilizer
Power supplyAC100-120V 50Hz
Temperature range100~300℃
Temperature control accuracy≤5℃
Heating time to high temperature≤ 25min
Container size Φ40mmx80mm
Glass bead container150g
Power120W
Dimension(WxDxH)mm135x150x155
Features:
1. Small glass bead sterilizer with small size, easy operation, and long service life.

2. Can LED digital display temperature, high can be heated up to 300℃.

3. Made of stainless steel container, with a high-performance heating element, high precision temperature controller, and over-temperature protection.

High-temperature sterilization glass bead sterilizer

glass-bead-sterilisation
Temperature control range100 - 300℃
Temperature control accuracy±5℃
Display accuracy1℃
Time setting1min - 99h59min
Temperature rise time﹤25minutes
Voltage specificationAC220V 60Hz
Power120W 250W
Vessel sizeΦ40mm*80mm Φ40mm*140mm
Glass bead capacity150g 300g
Dimension176*135*189.5mm 176*135*249.5mm
Net weight2.5kg 3.3kg
Features:
1. High-temperature sterilization glass bead sterilizer can reach 300 degrees Celsius, and the time setting can reach 99h59min, which can effectively achieve the sterilization effect.

2. Equipped with an LCD display, it can display the real-time temperature value and countdown display.

3. This autoclave glass bead sterilizer can effectively sterilize small solid metal and glass instruments within 10 minutes, which can quickly and efficiently eliminate bacteria and spores.

4. The inner chamber is made of stainless steel, with built-in over-temperature protection and a high-precision thermostat, and is equipped with a glass bead of 3.0mm diameter.

5. This high-temperature glass bead sterilizer is small in size and light in weight, with a silicone base, which is non-slip and smooth, and a dust cover, which is effective against dust.

Ceramic glass bead sterilizer

glass-bead-sterilizer-temperature
Heating core diameter36mm
Heating core materialceramic core
Input voltage AC220V
Temperature0 - 330℃
Frequency 50Hz
Average power consumption32W
Net weight2KG
Dimension180*100*200mm
Features:
1. The ceramic glass bead sterilizer uses the dry heat transfer principle for high-temperature sterilization and can be sterilized quickly within 5 to 15 seconds.

2. The outlet of the heating core is made of ceramic, which has a good heat insulation effect, is not easy to be scalded, and has good heat preservation.

3. The bottom of the ceramic glass bead sterilizer is equipped with anti-slip feet, which can effectively prevent slippage and increase the stability of the machine.

4. It adopts an electric box controller, which can effectively control the operation and control page cleaning, and is easy to operate.

5. The temperature of the inner core of the glass sterilizer can be 290 degrees Celsius, and the sterilization time for tissue and instruments is only 15 seconds.

Rapid glass bead sterilizer

glass-bead-sterilizer-dental
Power supplyAC200-240V 60Hz
Temperature range0~290℃
Temperature control accuracy≤ 5℃
Heating to the highest temperature used time≤ 20min
Container sizeΦ40mmx140mm
Glass bead container 300g
Power250W
Dimension135x150x205mm
Features:
1. Rapid glass bead sterilizer adopts stainless steel container, with the high-performance heating element, high precision temperature controller and over-temperature protection, short heating time, fast heating, shortening the preparation time.

2. The temperature inside the container with high-temperature beads can be heated up to about 300℃.

3. LED displays real-time temperature, the temperature can be set, equipped with a rotary knob to set the temperature.

4. A flashing indicator light means the instrument is running to the set temperature, bright indicator light means constant temperature, and no light means stop running.

5. The fast glass bead sterilizer is small in size, light in weight, easy to operate, and long in service life.

Mini glass bead sterilizer

bead-steriliser
Voltage120 or 240 V
Power50 W
Heating time to 240-250°C (482°F)approx. 10 minutes
ContainerStainless steel
Inner size3*4cm
InsulationAsbestos-free mineral wool
Size10*8.5*9cm
Net weight650g
Gross weight800g
Packing specification180*17*16cm
Features:
1. Mini glass bead sterilizer is smaller and less space-consuming, suitable for labs or medical rooms with little space.

2. The instrument is equipped with three fuses, safer and more secure in use.

3. LCD display, data display more clearly.

Glass bead sterilizer most crucial part - Glass bead

dry-bead-sterilizer
Glass bead is the most important part of the glass bead sterilizer, early glass bead sterilizers, generally use high-temperature glass beads between 1.5-2.0mm in diameter, the material is usually quartz sand material, hard and wear-resistant, odorless, strong thermal conductivity, and long use cycle, can be used repeatedly.
However, it should be noted that when using high-temperature glass beads, do not use them alone, but at the same time with a qualified standard sterilizer to use.

How to use glass bead sterilizer?

1. Fill the glass bead sterilizer with clean and dry glass beads to a depth of 50px below the edge of the container, do not use other fillers or liquids in contact with the container.

2. Turn on the sterilization switch and the internal temperature should reach about 240-270°C after the heating time indicated in the instruction manual, it will maintain the internal temperature with the switch on. Note: Do not touch the glass sterilization beads or the instrument before cooling.

3. Remove the metal lid and do not put it back on until the device is switched off to keep it ventilated inside and out.

4. Insert the dry device to be sterilized as deep as possible into the glass beads for at least 10 seconds.

5. The glass bead sterilizer can be used throughout the day without overheating, and, normally, the shell of the instrument may carry a heat equal to body temperature during the process. Besides, the glass bead sterilizer consumes very little energy, but it can only be used indoors.

6. After use, please turn off the switch and put the lid back in place to prevent dust and foreign objects from entering.

7. Glass sterilization must be replaced monthly or refilled after strict cleaning and drying by removing the glass beads and washing them with a mild soap solution and drying them after rinsing.

Precautions for using glass bead sterilizer

1. When filling the glass bead sterilizer with clean and dry glass sterilization beads, the depth standard is about 2cm below the edge of the stainless steel glass bead sterilization container, please do not use other fillers or liquids to contact the container.

2. Turn on the power switch, it takes some time to warm up before the container temperature reaches the set temperature, and it will keep the internal temperature while the power is on.

3. Do not touch the glass sterilization beads or the container before it cools down to avoid burns!

4. Insert the equipment to be dried and sterilized into the glass sterilization beads as far as possible for at least 10 seconds.

5. After use, please turn off the power switch and keep the lid closed to prevent dust and foreign objects from falling in.

6. The glass sterilization beads must be cleaned at least once a week and always wait until the instrument is completely cooled when removing the glass beads.

7. Strictly clean the glass bead sterilizer, dry it and refill it for use. Remove the glass beads and wash them with a mild soap solution and dry them after rinsing.

8. Warning: The glass bead sterilizer is not suitable for the following groups of people (including children): people with poor physical abilities, people with poor sensory sensitivity, and people who lack relevant experience and knowledge unless an additional person in charge can be ensured to ensure and supervise their safety of use. Children must be supervised to ensure that they are not exposed to hazards as a result of playing with the device.

How to order glass bead sterilizer?

ANTITECK provide lab equipment, lab consumable, manufacturing equipment in life sciences sector.
If you are interested in our glass bead sterilizer or have any questions, please write an e-mail to [email protected], we will reply to you as soon as possible.


    We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.
    Accept
    Privacy Policy