ANTITECK - Medical Device Assembly Automation Solution & Lab Equipment
biology-lab-equipment

How To Wash Pipette Tips?

Posted on September 2, 2024 by AntiTeckPipette

Pipette tips are one of the largest consumables in laboratories regarding the transfer of liquids. Their cleanliness is vital to minimize any interference that threatens the outcome. Pipette tips should be washed and sterilized for good use for a longer period and be accurate in your experiments. This article is a general guide on washing pipette tips, the correct procedures and techniques to follow, and other related information on the cleanliness of a laboratory. 

Tip loader for conductive pipette tip refill into empty rack, 48 boxes/hour, WhatsApp/WeChat/Mob: +86 133 1286 3972

Why Pipette Tips Must Be Thoroughly Washed 

It is very important to ensure that the pipette tips are clean and that there is no distortion of the results that may be obtained from the laboratory. Contaminated tips can bring impurities into your samples, thus giving you wrong readings and results and contaminating samples in various experiments. Such problems are prevented by the right cleaning of pipette tips, which makes your laboratory work more accurate.  

Pipette Tips and the Cleaning Specifications 

Pipette tips come in plastic and glass, and the two are different in the way that they are washed: 

  • Plastic Pipette Tips: These tips are often used in laboratories and are typically made of polypropylene or polystyrene. They are single-use items, but if they are multi-use, they must be washed and sterilized properly. 
  • Glass Pipette Tips: Although they are less popular than the other types, glass tips are employed where such characteristics as chemical inactivity or high precision are desirable. These reusable tips must be washed well to remove residues and minimize cross-contamination. 
pipette-tips-rack

A Simple Guide to Washing Pipette Tips 

1. Preparation 

First of all, let’s list all the materials that will be needed before starting the cleaning process: 

  • The wash basin or sink must be clean 
  • Water with mild soap or laboratory soap 
  • Deionized or distilled water 

Wash the utensils, such as brushes or any other items used in cleaning, if necessary. If required, use a brush or a cleaning tool. Ensure the washing area is clean so no new particles are transferred to the tips. 

2. Rinsing 

The first step is to rinse the pipette tips with running water so there is no droplet of the previous liquid in the tips. Wash the utensils with a water jet that is not very strong so that water does not splash and wash away all the deposits that can be seen. 

3. Washing with Detergent 

Wash the pipette tips in a container with warm water, mild detergent, or any other solution suitable for laboratories. This should be done using a soft brush or any other cleaning tool to carefully clean the tips, especially when there is a deposit. Do not use any product that can in any way or another endanger the tips on the tips. For tips with intricate patterns or very small holes, the cleaning solution has to get into the holes. 

4. Rinsing Thoroughly 

It was suggested that pipette tips be washed with soap and then deionized or distilled water. This step is important as no detergent is in the beaker, which will affect the measurements. Wash until the water is clear and bubbles are not formed at the bottom of the container. 

5. Drying 

To eliminate lint, the pipette tips should be wiped on a clean, lint-free cloth or left to dry on a clean surface. It is advised not to use paper towels or cloths that may shed string or debris on the material’s surface. This is because moisture may get to the tips. Therefore, it is always a requirement to make sure that the tips are dried before use or storage.  

6. Sterilization (if required) 

In the case of pipette tips that can be used several times or for those working in a very sensitive area, the pipette tips should be washed to remove the microorganisms. Common sterilization methods include: 

  • Autoclaving: Place the tips into an autoclavable container and follow the directions for the autoclave regarding temperature and pressure. 
  • UV Sterilization: Put the tips in a UV sterilizer so that the tips may be exposed to ultraviolet light, eliminating microorganisms. Ensure the tips are well positioned in the sterilizer to be properly exposed. 
  • Chemical Sterilization (ETO sterilizer): Depending on the materials to be sterilized, ethanol or bleach solutions are examples of chemical sterilants. Employ the concentrations and exposure times that the manufacturer recommends for the chemicals. 

7. Inspection 

One of the things that should also be done while cleaning and sterilizing pipette tips is to inspect the tips for any residues, particles, or signs of damage. Discolored, stained, or in any way that may appear unhygienically clean should be discarded and washed afresh.  

pipette-tips-box-of-1-ml

Pipette Tip Care: Correct Use: An Information Guide 

  • Regular Cleaning Schedule: Create a cleaning schedule based on usage and the properties of the products and materials being treated. 
  • Use Dedicated Cleaning Equipment: Pipette tips must not be used for other pipettes, and different cleaning tools and receptacles should be used. 
  • Proper Handling: When handling pipette tips, use clean gloves or tongs to avoid adding more contaminants to the cleaning process. 
  • Store Tips Properly: Pipette tips should be clean and sterilized and stored in a clean, dust-free environment. To prevent contamination, ensure that the products are placed in well-sealed containers or on sealed racks. 
  • Monitor for Wear and Tear: As a part of the maintenance of pipette tips, it is recommended that one should look for any signs of damage, such as cracks or warping on the outer edges, at least once a week. Tips that are damaged should be replaced so that precision is not affected and leakage is avoided.

Troubleshooting Common Issues 

  • Residue Remains: If residue remains after washing, use a stronger cleaning solution or change the technique. Wash the samples with distilled water to ensure that all the cleaning agents are washed away so that they do not influence the results. 
  • Deformation: If pipette tips are distorted, it could be due to heat or poor handling. The tips should not be damaged during cleaning, so appropriate tools and solutions should be used. 
  • Contamination: If contamination problems are apparent, assess the cleaning process and the cleanliness of all the equipment and material used. 

Conclusion 

Therefore, pipette tips should be cleaned and maintained correctly not to affect the laboratory tests conducted. By adhering to the procedures and guidelines outlined above, you can maintain clean and functional pipette tips, enhancing the results of your experiments. Some of the most vital standards that should be followed in any laboratory include cleaning, handling, and sterilization

FAQ 

Q1. To what extent do pipette tips require cleaning? 

In cases of accurate work or when pipette tips are to be used on reactive substances, it is recommended that they be washed after use. For less frequent use, cleaning may be done every few days. 

Q2. Are pipette tips reusable? If yes, how can they be reused, washed, and stored? 

Reusable tips are safer than disposable tips and can be used if cleaned and sterilized properly. They should be protected from contaminants in a clean and properly closed container. 

Q3. If pipette tips are damaged after cleaning, what should be done? 

They should also be changed more often because they get worn out, distort the measurement, and can be a source of contamination. 

Recent Posts

We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.
Accept
Privacy Policy